UPDATED STREETBLOCK PLAN (URA/DC PLAN RELEASE 7/95E) FOR THOMSON GARDEN ESTATE
General
2 October 1995
This article has been migrated from an earlier version of the site and may display formatting inconsistencies.
Circular No : URA/PB/95/18 - DCD
Our Ref : DC 602/11-6
Fax : 3216501
PROFESSIONAL INSTITUTES
We refer to our streetblock plan (URA/DC Plan Release 1/95E) for Thomson Garden Estate dated 23 Jan 95.
We would like to inform you that the front setback of 2.4m for carporch is no longer required. Carporch, terrace and patio area at the front are allowed to abut the front site boundary except for columns which should be setback 2.4m. This relaxation is to take into account the shorter front building setback of 5m. The complete setback requirements are tabulated in Table 1 and an updated plan (URA/DC Plan Release 7/95E) is attached for your easy reference. This will supersede our earlier streetblock plan (URA/DC Plan Release 1/95E) for Thomson Garden Estate.
I would appreciate it if you could convey the contents of this circular to relevant members of your organisation.
If you or your members have any queries about this circular, please do not hesitate to call Planner Ms Rosemary Pang at Tel: 6321-8089. Our DCD Customer Service Hotline (Toll-free) at Tel: 1800-223 4811 would also be pleased to answer queries on this, and indeed any other development control matter.
Thank you.
Thank You.
LAM KWOK WENG
DIRECTOR
(DEVELOPMENT CONTROL)
for CHIEF PLANNER
URBAN REDEVELOPMENT AUTHORITY
URA/DC PLAN RELEASE 7/95 E
Thomson Garden Estate
The purpose of this plan is to inform the public of an updated plan for regulating developments in the area.
The form of development allowed within the area is mixed landed housing development not exceeding 3 storeys* and this shall supersede the relevant portion of the existing Micro-zoning Plan Part 24.
Table 1 Setback control for Thomson Garden Estate
Table caption
Landuse | Residential |
|---|---|
Building form | Mixed Landed housing |
Setback control | Carporch & terrace Front : Roof eaves - Zero Main building Front : 5.0m Side : 1st & 2nd storeys - 2.0m 3rd storey - 3.0m Rear : 3.0m** |
Height control | Up to 3-storey |
Footnote :
* The floor to floor height control for residential development are 4.5 m for the 1st storey and 3.6 m for the upper storeys.
** The rear building setback has been relaxed from 3m to 2m since 1 Apr 2002 (circular URA/PB/2002/08-DCD).
Where relevant, Envelope Control Guidelines for landed housing may be applicable. Please refer to the circular URA/PB/2015/02-DCG.