URA/CUD Plan Release 1/2014E Street Block Plan for House Nos. 65, 69 & 70 Mohamed Sultan Road, 20, 22, 38 & 50 Martin Road, 11 Arnasalam Chetty Road and 9 Muthuraman Chetty Road (River Valley Planning Area)
Development Control
Street Block
Urban Planning and Design
6 June 2014
Circular No : URA/PB/2014/08-CUDG
Our Ref : DC/ADMIN/CIRCULAR/PB_14
Fax : 6220 3201
CIRCULAR TO PROFESSIONAL INSTITUTES
Who Should Know:
Building owners, Qualified Persons and developers
Effective Date:
With effect from 06 June 2014
Objective
A review has been carried out for the Street Block along Mohamed Sultan Road, Martin Road, Arnasalam Chetty Road and Muthuraman Chetty Road in response to recent new developments. The guidelines have been revised with the aim to create more attractive and pedestrian-friendly streets with a continuous street edge along Mohamed Sultan Road and Martin Road, flanked by commercial activities at street level. This will build on the current character and mix of retail, food and beverage uses within the neighbourhood.
As such, sites fronting Mohamed Sultan Road and Martin Road are guided to be developed for Commercial or Residential with Commercial at 1st Storey use according to the Land Use reflected in the Master Plan, to be built up to the lines of Road Reserve and to include an integrated covered walkway lined by commercial activities at the 1st Storey.
This Street Block Plan will be used to guide addition & alteration works as well as redevelopment proposals within the above-mentioned street blocks. This supersedes the previous Street Block Plan for the area (Circular URA/PB/2008/23-CUDD dated 5 December 2008).
Details of Guidelines
Planning parameters and urban design guidelines covered by this Street Block Plan include the type of land use, building height, form of development, building setback requirements and vehicular access. The prescribed guidelines are tabulated and shown in Annex A below. These are intended to complement and shall be read together with the existing Development Control (DC) Guidelines for Residential Developments.
I would appreciate it if you could convey the contents of this circular to the relevant members of your organisation. If you or your members have any queries concerning this circular, please do not hesitate to email us. We will be pleased to answer queries on this subject, and any other development control matters. For your information, our past circulars to the professional institutes are available from our website http://www.ura.gov.sg.
Thank You.
FUN SIEW LENG (MS)
GROUP DIRECTOR (URBAN PLANNING & DESIGN)
for CHIEF EXECUTIVE OFFICER
URBAN REDEVELOPMENT AUTHORITY
Annex A
STREET BLOCK PLAN FOR HSE NOS. 65, 69 & 70 MOHAMED SULTAN ROAD, 20, 22, 38 & 50 MARTIN ROAD, 11 ARNASALAM CHETTY ROAD AND 9 MUTHURAMAN CHETTY ROAD (RIVER VALLEY PLANNING AREA)
Table 1
PARAMETERS | REQUIREMENTS | |||
Hse. Nos. 65, 69 & 70 Mohamed Sultan Road; | Hse. Nos. 20 & 22 Martin Road | 38 (Rear Plot From Martin Road) Martin Road and | ||
1 | Land Use* | Residential with Commercial at 1st Storey | Commercial | Residential |
2 | Gross Plot Ratio | Maximum 2.8 | ||
3 | Building Height | Maximum 15 storeys | ||
4 | Building Setback / Building Edge# | Road Reserve The development at Hse No. 50 Martin Road is to be set back a minimum of 3.0m along the common boundary. | Developments can either be built up to the lines of Road Reserve to a minimum height of 1 storey, with a covered walkway OR set back from the lines of Road Reserve to comply with the prevailing Development Control Guidelines without a covered walkway as shown in Appendix 1 [PDF, 881.86 KB]. | |
The developments are to be set back along the rear and side boundaries in accordance with the prevailing Development Control Guidelines as shown in Appendix 1. [PDF, 881.86 KB] | ||||
5 | Covered Walkway | A minimum 3.6m wide (and 3.0m clear) or minimum 3.0m wide (and 2.4m clear) covered walkway is to be provided within the development at the 1st storey abutting the lines of Road Reserve as shown in Appendix 1. [PDF, 881.86 KB] The requirements for the covered walkways are:
| ||
6 | Service Areas | All service areas, mechanical and electrical (M&E) equipment, water tanks, car parking lots, etc, are to be located within the building envelope, be fully integrated with the main building and visually screened from the top and on all sides. Relevant Circulars: | ||
7 | Vehicular Access | All vehicular access to the developments are to be taken from the local access roads – Arnasalam Chetty Road, Narayanan Chetty Road or Muthuraman Chetty Road, where possible. | ||
Updated on 26 February 2026
* Please refer to the prevailing Master Plan land use zoning. Where there is any discrepancy, the Master Plan land use zoning shall prevail.
# The plot for road widening is required by LTA to be vested free of charge in the State with vacant possession and free from encumbrances prior to issue of CSC for the development.